Pipeline Run-Failure Notifications via dagster-apprise
Context
Platform alerting (docs/docs/2_platform/3_deployment_guide/5_monitoring_and_alerting/) delegates to external observability (SigNoz/PagerDuty/etc.) via OpenTelemetry. That path doesn't reliably surface Dagster run failures: crashed observation jobs and failed asset materializations show up in the Dagster UI but nobody gets notified. We need a direct, pipeline-native failure signal that also covers asset-centric pipelines, where most runs are spawned indirectly by AutomationConditionSensorDefinition.
Decision Drivers
- Coverage of asset-centric runs
Must catch auto-materialize failures, not only explicit-job failures. - Minimal custom code
Pipelines aren't a notifications product; every line of delivery code is a line we maintain. - Broad channel support
Slack today, Teams/email/PagerDuty on demand, without a new codepath per channel. - Opt-in
No URLs configured → no sensor, no runtime noise. - Inheritable by default pipelines
Operators turn notifications on by setting config, not by redeploying code.
Decision
Use dagster-apprise behind a thin library wrapper and wire it into every Definitions builder.
- Primitive:
@run_failure_sensorwithoutmonitored_jobs— one sensor per code location catches every failed run, including the ones auto-materialize spawns. - Factory:
run_failure_notification_sensor()inpackages/pipeline/swiss_ai_hub/pipeline/sensors/run_failure_notification_sensor.pywrapsAppriseResource.notify_run_status. Our message body contributes asset keys (truncated to 5) and error preview (truncated to 500 chars); job name, run id, and the deep link ({base_url}/runs/{run_id}) are added byAppriseResource.notify_run_statusitself viaAppriseConfig.base_url. - Automatic wiring:
run_failure_notification_sensors_from_settings()lives in the same module and readsNotificationSettings; eachdefault_*_definitions()builder spreads it into itssensors=[...]. Apps inapp/default_rag_pipeline/,app/shared_rag_pipeline/, andplayground/inherit the sensor unchanged. - Consumer escape hatch: manual compositions import
run_failure_notification_sensordirectly and pass customurls/monitored_jobs. - Env propagation — three-way split so only secrets live in operator env files:
- Operator env (secrets):
NOTIFICATION_URLSonly; empty = disabled. - Compose template (stage-derived):
NOTIFICATION_DAGSTER_UI_BASE_URLcomputed fromstage/${DOMAIN}. To override when Dagster is hosted on a non-standard subdomain, edit theNOTIFICATION_DAGSTER_UI_BASE_URLline in the generatedinfra/docker-compose.<stage>.yml. compose-config.yml(platform defaults):NOTIFICATION_TITLE_PREFIXandNOTIFICATION_MIN_INTERVAL_SECONDSbaked into the generated compose files.
- Operator env (secrets):
Consequences
Positive
- One sensor catches both explicit-job and auto-materialize failures across the whole code location; no per-asset wiring as pipelines grow.
- Adding a notification channel = setting a URL, not writing code. 80+ services via Apprise.
- Opt-in via env: dev stacks and anyone not operating production stay quiet.
- Default pipelines (
default_rag_pipeline,shared_rag_pipeline) inherit the behaviour — enabling it is a config change, not a redeploy. - Operator env surface is minimal: only
NOTIFICATION_URLS(which carries secrets) is operator-visible; UI URL is stage-derived, other defaults live incompose-config.yml.
Trade-offs
- Adds
dagster-appriseandappriseaspackages/pipelinedependencies (~2 MB). - Operators learn the Apprise URL format instead of N per-channel env vars.
- Sensor runs inside the code-location containers, not the daemon — the notification config must reach those containers (already handled by the compose template).
- Complementary to OTEL alerting, not a replacement: covers Dagster run lifecycle only. Request-path, LLM, and infra failures still flow through OTEL/SigNoz.
- Error previews may leak internal details to notification channels. The 500-char preview can include file paths, DB names, query fragments, or credentials embedded in connection strings. Truncation bounds the blast radius but does not redact. Operators sending failures to shared or public channels should keep this in mind; if it becomes a problem we can downgrade to exception type + first line.
- Backup Dagster (
packages/backup, :3004) is intentionally out of scope. It runs its own Dagster instance and builders; failure notifications for backup/restore runs are a follow-up. Revisit if backup failures become a recurring ops blind spot.
Related Decisions
docs/docs/2_platform/3_deployment_guide/5_monitoring_and_alerting/index.en.md— Establishes that alerting is externalised via OpenTelemetry/SigNoz. This ADR is the documented exception for Dagster run-lifecycle signals, which don't reliably surface through that path.